General information

The Interlocking panel system is designed for any facade to be cladded with a rainscreen system, for both new and refurbishment projects.

It involves installing interlocking panels on metal or wood framework fixed to the supporting structure (masonry or metal structure).

The metal facade panels are simply connected by the use of an interlocking groove giving the elegant appearance of a recessed joint.

Panels can be perforated.


Technical data

Thickness0.8 mm & 1 mm
Standard Center to Center150 mm
220 mm
300 mm
Maximum Length of Panel3 meters
Support SystemFramework of galvanized steel or aluminium rails fixed every 600 mm on the main structure
  • ANTHRA-ZINC.jpeg
    ANTHRA-ZINC
  • AZENGAR.jpg
    AZENGAR
  • PIGMENTO_Blue.jpeg
    PIGMENTO Blue
  • PIGMENTO_brown.jpeg
    PIGMENTO Brown
  • PIGMENTO_green.jpeg
    PIGMENTO Green
  • PIGMENTO_red.jpeg
    PIGMENTO Red
  • QUARTZ-ZINC.jpg
    QUARTZ-ZINC

Documents and drawings

  • The panels are installed in a sequential order from top to bottom for horizontal panels. The upper edge of each panel is engaged into the lower edge of the panel above. The panels are mechanically attached using screws and/or the panel fixing clip that allows for thermal movement. The panels should be installed with the protective film in place.